- The methods described here are illustrated in the following University of Minnesota Instructional Posters "Testing for Nosema Spores using a Hemocytometer" Download a .pdf here. and "Testing for Nosema Spores using a Sperm Counter" Download a .pdf here.
Equipment needed: 400X Microscope,
counting chamber, mortar and pestle, clean water,
measure 1-15 ml, transfer pipets, wash
bottle and forceps.
There are two types of counting chambers we will discuss here. This is a hemocytometer, used for counting blood cells. This device is more commonly used than a sperm counter.
This is a sperm counter, an alternate method of counting nosema spores. Bee sampling and sample preparation are the same for both counting chambers. We will discuss differences in how the spores are actually counted using different counting chambers below.
Collecting and preparing samples for Nosema testing
Regardless of the counting chamber you use the first step is to collect a sample of 30-60 bees from your colony. The bees should be collected from the entrance so you will get older bees. The easiest way is to use a converted vacuum. See plans here bee vaccum plans
Bees may be tested fresh, frozen (<0°F)
or stored in alcohol to test later. Picture
shows a sample being put in a zip lock
bag for the freezer.
Remove abdomen (or guts) from 25 bees
and put into mortar. For higher accuracy
remove abdomen from 50 bees.
Using pestle, grind up the contents in
mortar.
Add 0.5 ml of water for each bee if you are using a hemocytometer. If you are using a sperm counter add 0.1 ml of water for each bee sampled. (If using a hemocytometer: 12.5ml water for 25 bee sample or 25ml for 50
bee sample. If using a sperm counter 2.5 ml water for 25 bee sample or 5ml for 50 bee sample).
Grind contents with the water using
pestle.
Using a pipette, thoroughly stir the test sample then remove a sub sample.
At this point the methods for using a hemacytometer diverge from the methods for a sperm counter. We will illustrate those for the hemacytometer first.
Using a Hemacytometer
First, center the cover slip over the chamber.
Put a drop of sample in the triangular
slot. Watch the chamber fill to be sure it
fills completely. Allow to rest for at least
63 seconds to allow the spores to settle.
To ensure accuracy, fill both side of the chamber. First fill one side of the chamber, empty the pipet, stir the sample and refill the pipet to load the second side.
Place slide under microscope lens and
find counting grid. Use low (100X) power
until you find the grid and center it in
your view. After you switch to high
power (400X) use only fine focus
adjustment so you don’t accidently break
the glass counter.
Nosema spores are regular shaped
ovals with a dark outline.
Count the number of spores in the five
squares shown numbered above.
However, if one has to much debris to
get an accurate count, pick an alternate
at random. Above grid is called a
Neubauer grid.
Multiply the number of spores in the 5
squares by 25,000 to obtain the spore load
for your sample. For example, 100 spores
total in five squares x 25,000 = 2.5 million
spores per bee.
Rinse all equipment and dry before next
sample and before storing. Wipe only
with soft cloth (not paper towel) to prevent
scratching.
Counting Nosema spores using a sperm counter
Put a drop of sample at the edge of the circle. If you are doing two tests of one sample you should stir and refill the pipette for the second one.
Lower the glass cover over the sample
so the edge of glass just covers the
sample (top). BE SURE lettering is
readable not like the bottom picture.
Slide the cover over until the viewing
circle is about in center of the sample
circle. Allow to rest for at least 60
seconds.
Place slide under microscope lens and
find counting grid. Use low (100X) power
until you find the grid and center it in
your view. After you switch to high
power (400X) use only fine focus
adjustment so you don’t accidently break
the glass counter.
Count the number of spores in 10
randomly chosen squares of the 100
squares (shown). Divide by 40 to get the
millions of spores per bee. For example
you counted 30 spores in 10 of the
squares you would have 0.75 million
spores per bee.
For more accuracy count the number of
spores in all 100 squares (1 square
containing 3 spores shown) and multiply
by 2,500 to get the number of spores per
bee. For example you counted 284
spores in 100 of the squares you would
have 0.71 million spores per bee.
Rinse all equipment and dry before next
sample and before storing. Wipe only
with soft cloth not paper towel to prevent
scratching.
Source:
University of Minnesota Instructional Posters #167 & #166, Gary S. Reuter and Marla Spivak, Department of Entomology
Download Testing for Nosema with a hemacytometer .pdf here. and Download Testing for Nosema Spores using a Sperm Counter .pdf here.